Gold standard MVHR ventilation servicingAt Flexivent we understand the importance of maintaining and servicing domestic ventilation systems.

It is recommended that an MVHR heat recovery System is serviced annually. This will ensure your system is set up correctly and working to its full potential.

Flexivent are pleased to be able to offer a comprehensive full system service at a competitive price for not just Mechanical Ventilation with Heat Recovery (MVHR), but also Mechanical Extract Ventilation (MEV) and Positive Input Ventilation (PIV or PPU).

We provide ventilation servicing and maintenance from our Gloucestershire base, and additionally cover Bristol, Cardiff, Avon, Worcestershire, Oxfordshire, Wiltshire, Monmouthshire, Herefordshire and the West Midlands.

Mechanical Ventilation with heat Recovery (MVHR or HRV) system servicing

After a thorough overview of the system we will carry out the following::

  • Our specialist NICEIC qualified engineer will perform a visual inspection to identify issues such as air leaks, excessive noise, blocked condensate drains, dirty and polluted heat exchanger (heat cube) and motors, damage to visible ducting and potential design and control issues.
  • Carry out a clean of the internal motors to include removal of dust and debris which can impact motor performance and then thoroughly sanitise the interior of the unit.
  • Clean and then sanitise the internal heat exchanger (heat cube) to aid in the efficiency of the system.
  • Replace the system filters with new.
  • Instruct in the fitting and supply a replacement set of new filters for interim fitting, after 6 months, by the end user.
  • Thorougly vacuum and clean with antibacterial sanitising spray the rooms extract and supply air valves and accessible duct connections.
  • Check external extract and supply vents, if safely accessible, and clean debris and confirm that the airflow rates are correctly balanced.
  • Check air flow rates and rebalance and adjust the system, if necessary, to comply with required airflow rates outlined in the Goverment legislation on ventilation: Approved Document F (updated June 2022).
  • Issue a certificate and servicing report.

Please click below to take advantage of our free no obligation quote.

Mechanical Extract Ventilation (C-MEV) system servicing

After a thorough overview of the system we will carry out the following::

  • Our specialist NICEIC qualified engineer will perform a visual inspection to identify issues such as air leaks, excessive noise, blocked condensate drains, dirty motors, damage to visible ducting and potential design and control issues.
  • Carry out a clean of the internal motor to include removal of dust and debris which can impact motor performance and then thoroughly sanitise the interior of the unit.
  • Replace the system filters (if applicable) with new.
  • Instruct in the fitting and supply a replacement set of new filters (if applicable) for interim fitting, after 6 months, by the end user.
  • Thorougly vacuum and clean with antibacterial sanitising spray the rooms extract air valves and accessible duct connections.
  • Check external extract vent, if safely accessible, and clean debris out if found
  • Check air flow rates and rebalance and adjust the system, if nessarry, to comply with required airflow rates outlined in the Goverment legislation on ventilation: Approved Document F (updated June 2022).
  • Issue a certificate and servicing report.

Please click below to take advantage of our free no obligation quote.

Positive Input Ventilation (PIV or PPU)

After a thorough overview of the system we will carry out the following:

  • Our specialist NICEIC qualified engineer will perform a visual inspection to identify issues such as, excessive noise, dirty motors, damage to the PIV unit and potential design and control issues.
  • Carry out a clean of the motor to include removal of dust and debris which can impact motor performance and then thoroughly sanitise the interior of the unit.
  • Replace the filters with new.
  • Thorougly vacuum and clean with antibacterial sanitising spray the supply grille and accessible duct connections.
  • Check air flow rate with regard to manufacturers recommendations and rebalance and adjust the system, if necessary .
  • Issue a certificate and servicing report.

Please click below to take advantage of our free no obligation quote.

Maintenance of all popular makes & models of residential ventilation systems

heat exchanger vent axia mvhrAt Flexivent we are pleased to be able to offer servicing & maintenance for residential ventilation systems for all popular makes and models including Vent Axia, Vectaire, Nuaire, Envirovent, Domus, Greenwood, Beam, Dantherm, Titon, Airflow, Zehnder, Ubbink, Blauberg, Lindab, Xpelair, Vortice, Brookvent and many more.

Flexivent  are NICEIC qualified, experienced, trusted and independent ventilation contractors helping to look after your indoor air quality through installation, commissioning, servicing and maintenance.

Please click below to take advantage of our free no obligation quote.

Benefits of regular servicing & maintenance

mvhr filters

Letting flexivent service and maintain your system regularly will ensure you continue to benefit from good air quality

It is vital to ensure effective and efficient operation making sure that allergens and moisture are extracted improving indoor air quality.

Additionally, regular servicing can lead to a quieter running system with reduced running costs, and is essential to extend the product life of your system. Regular servicing will also help to avoid costly repairs. Please be aware, failure to service your system regularly could affect the warranty on your unit.